---
title: "TCLP Test and SPLP: Steps, Limits, Hold Times - Prisma LIMS"
description: "TCLP and SPLP in plain words: what each leaching test is for, the steps, the two hold-time clocks, and what a LIMS must track from sample to leachate."
image: https://prismalims.com/hubfs/website%20assets/images/featured%20images/og-tclp-splp-leaching.jpg
---

[Skip to content](https://prismalims.com/tclp-splp-leaching#main)

[![Prisma LIMS](https://prismalims.com/hs-fs/hubfs/website%20assets/logos/prisma-lims-logo-1-line-340.webp?width=170&height=30&name=prisma-lims-logo-1-line-340.webp)](https://prismalims.com/) [Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

- [Home](https://prismalims.com/)
- [How You Get Live](https://prismalims.com/how-it-works)
- [Who It’s For](https://prismalims.com/who-its-for)
- Labs we serve
  
    - [Environmental LIMS](https://prismalims.com/environmental-lims)
    - By sample type 
          - [Water LIMS](https://prismalims.com/who-its-for#water)
          - [Wastewater LIMS](https://prismalims.com/wastewater-lims)
          - [Drinking water LIMS](https://prismalims.com/drinking-water-lims)
          - [Soil, sludge and biosolids](https://prismalims.com/soil-lims)
    - By lab type 
          - [Commercial environmental labs](https://prismalims.com/commercial-lab-lims)
          - [Municipal and treatment-plant labs](https://prismalims.com/municipal-lab-lims)
- Guides
  
    - [Cloud LIMS](https://prismalims.com/cloud-lims)
    - [Chain of custody software](https://prismalims.com/chain-of-custody-software)
    - [Sample holding times](https://prismalims.com/sample-holding-times)
    - [TCLP and SPLP](https://prismalims.com/tclp-splp-leaching)
    - [PFAS testing](https://prismalims.com/pfas-testing-lims)
    - [NELAP and TNI records](https://prismalims.com/nelap-tni-lims-requirements)
    - [LIMS cost over five years](https://prismalims.com/lims-total-cost-of-ownership)
    - [Compare environmental LIMS vendors](https://prismalims.com/compare)
    - [Blog](https://prismalims.com/blog)
- [About Us](https://prismalims.com/about)

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

1. [Home](https://prismalims.com/)
2. [Environmental LIMS](https://prismalims.com/environmental-lims)
3. TCLP and SPLP

Leaching tests and metals

# TCLP test and SPLP: what your LIMS must track

TCLP (EPA SW-846 Method 1311) is a lab test that measures how easily contaminants move out of a waste. A drum of spent blast media needs a waste profile before it can leave the site. Its jar reaches the lab with TCLP metals and semivolatiles on the chain of custody. The clocks started at collection: 14 days to the TCLP extraction for the semivolatiles, 180 days for the metals (Method 1311). This guide is for environmental labs that run leaching tests and metals: what TCLP and SPLP are, how a TCLP test runs, its hold-time clocks, and what your LIMS has to keep.

By the Prisma LIMS team · Updated 26 November 2026

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea) [See the TCLP steps](https://prismalims.com/tclp-splp-leaching#steps)

In short

TCLP (EPA SW-846 Method 1311) is a lab test that measures how easily contaminants move out of a waste. Under 40 CFR 261.24, its result decides whether the waste has the toxicity characteristic. SPLP (Method 1312) is a similar test for liquids, soils and wastes. Both add an extraction step, so the lab tracks the parent sample, the leachate and two hold-time clocks. Prisma LIMS, a cloud LIMS built only for environmental labs, supports TCLP and SPLP workflows, and we set them up for your lab.

On this page

1. [Why the result must hold up](https://prismalims.com/tclp-splp-leaching#why)
2. [TCLP and SPLP in plain words](https://prismalims.com/tclp-splp-leaching#what)
3. [How a TCLP test runs](https://prismalims.com/tclp-splp-leaching#steps)
4. [The hold-time clocks](https://prismalims.com/tclp-splp-leaching#clocks)
5. [TCLP metals and limits](https://prismalims.com/tclp-splp-leaching#metals)
6. [What a LIMS must track](https://prismalims.com/tclp-splp-leaching#track)
7. [How Prisma LIMS supports it](https://prismalims.com/tclp-splp-leaching#prisma)
8. [Questions](https://prismalims.com/tclp-splp-leaching#questions)

Why it matters

## Why does a TCLP result have to hold up?

A TCLP result decides if a waste is hazardous under the federal toxicity rule. Your client uses it to decide where the waste can go. As a result, the number has to stand up when someone checks how you got it.

There is little room for error. In fact, EPA calls Method 1311 a Method-Defined Parameter: it “may not be modified” when used for RCRA testing. One wrong fluid, one skipped filter step, or a late extraction can sink the result.

The clock matters too. If a hold time runs out, Method 1311 says the values are only “minimal concentrations.” They can still show a waste is over the limit. They can never show it is under.

The two tests

## What are TCLP and SPLP?

### TCLP: SW-846 Method 1311

**TCLP** is the Toxicity Characteristic Leaching Procedure, EPA SW-846 Method 1311. EPA says it is “designed to determine the mobility of both organic and inorganic analytes present in liquid, solid, and multiphasic wastes”.

In other words, it shows how much of a contaminant can leach out of a waste. A waste has the toxicity characteristic when its TCLP extract holds a listed contaminant at or above its Table 1 level. That rule is 40 CFR 261.24.

### SPLP: SW-846 Method 1312

**SPLP** is the Synthetic Precipitation Leaching Procedure, EPA SW-846 Method 1312. It measures the same kind of mobility, in liquids, soils and wastes. Its fluids are dilute sulfuric and nitric acid, or plain reagent water.

For soils, the fluid depends on where the site is. Method 1312 uses fluid #1 east of the Mississippi River and fluid #2 west of it. Wastes and wastewater use fluid #1. Cyanide and volatiles use reagent water.

### TCLP vs SPLP

| Point | TCLP (Method 1311) | SPLP (Method 1312) | Source |
| --- | --- | --- | --- |
| What it measures | Mobility of organic and inorganic analytes in liquid, solid and multiphasic wastes | Mobility of organic and inorganic analytes in liquids, soils and wastes | Method 1311 Method 1312 |
| Rule it serves | Named in 40 CFR 261.24, the toxicity characteristic | Not the test named in 40 CFR 261.24 | 40 CFR 261.24 |
| Extraction fluid | Acetic acid fluid #1 or #2, picked by a pH test on the solid. Volatiles always use fluid #1. | Sulfuric and nitric acid fluid #1 or #2, or reagent water (#3) for cyanide and volatiles | Method 1311 Method 1312 |
| Hold times | Set in the method’s own table | Same table as TCLP | [See the clocks](https://prismalims.com/tclp-splp-leaching#clocks) |

Step by step

## How does a TCLP test run, step by step?

The nonvolatile path of Method 1311, in six steps. Volatiles follow the same idea in a zero-headspace extractor (ZHE).

1. 1
   
   ### Check the waste first
   
   Find the percent solids on at least 100 grams. If the waste has less than 0.5% dry solids, the filtered liquid is the TCLP extract.
2. 2
   
   ### Size the solids
   
   Cut or grind the solid so it passes a 9.5 mm sieve, unless it already does.
3. 3
   
   ### Pick the fluid
   
   A pH test on 5 grams of the solid picks extraction fluid #1 or #2. Record which one you used.
4. 4
   
   ### Tumble it
   
   Add fluid at 20 times the weight of the solid. Rotate end over end at 30 ± 2 rpm for 18 ± 2 hours, at 23 ± 2 °C.
5. 5
   
   ### Filter the leachate
   
   Filter through a 0.6 to 0.8 µm glass fiber filter. Combine it with the first liquid phase, or test both and take a volume-weighted average.
6. 6
   
   ### Preserve and test
   
   Acidify the metals portion to pH below 2. Send portions to metals, VOC or SVOC analysis. Compare the results to the regulatory levels.

Two clocks

## What are the hold times for TCLP and SPLP?

A leaching test runs on two clocks. One runs on the sample, one on the leachate.

Clock 1: field collection to the TCLP extraction

Clock 2: the TCLP extraction to the analysis

The first clock starts when the sample is collected and stops at the TCLP extraction. The second clock starts at the extraction and stops at the analysis. Semivolatiles add a prep extraction step in the middle.

| Analyte group | Collection to TCLP extraction | TCLP extraction to prep extraction | Prep extraction to analysis | Total | Source |
| --- | --- | --- | --- | --- | --- |
| Volatiles | 14 days | Not used | 14 days | 28 days | Method 1311 |
| Semivolatiles | 14 days | 7 days | 40 days | 61 days | Method 1311 |
| Mercury | 28 days | Not used | 28 days | 56 days | Method 1311 |
| Metals, except mercury | 180 days | Not used | 180 days | 360 days | Method 1311 |

Method 1312 (SPLP) has the same table. Your permit, your state or your client may set a tighter rule. Always check the current method.

For hold times on other tests, see our guide to [sample holding times and how a LIMS tracks them](https://prismalims.com/sample-holding-times).

TCLP metals

## What are the TCLP limits for metals?

40 CFR 261.24 Table 1 lists 40 contaminants. Eight are metals.

| Metal | EPA hazardous waste number | Regulatory level (mg/L) | Source |
| --- | --- | --- | --- |
| Arsenic | D004 | 5.0 | 40 CFR 261.24 |
| Barium | D005 | 100.0 | 40 CFR 261.24 |
| Cadmium | D006 | 1.0 | 40 CFR 261.24 |
| Chromium | D007 | 5.0 | 40 CFR 261.24 |
| Lead | D008 | 5.0 | 40 CFR 261.24 |
| Mercury | D009 | 0.2 | 40 CFR 261.24 |
| Selenium | D010 | 1.0 | 40 CFR 261.24 |
| Silver | D011 | 5.0 | 40 CFR 261.24 |

### From leachate to the instrument

The metals portion of the extract is acidified with nitric acid to pH below 2. It is then acid digested, unless digestion would lose the metal. SW-846 Method 3010A is one digestion for extracts headed to ICP.

The digested extract then goes to the instrument, often an ICP. SW-846 Method 6010D uses ICP-OES and Method 6020B uses ICP-MS (6010D, 6020B). Mercury in leachate has its own cold-vapor method, SW-846 Method 7470A. For water and wastes, EPA has Methods 200.7 (ICP-AES) and 200.8 (ICP-MS) (200.7, 200.8).

Method 1311 adds one more rule for metals. Say a metal’s recovery is under 50%. If its result is under the limit but within 20% of it, the lab must use the method of standard additions. Your LIMS has to know when that applies.

### What a metals testing lab needs from its LIMS

- 40 CFR 136.3 lets a lab report total hardness as calcium plus magnesium, as their carbonates. So the LIMS must hold hardness as a calculated analyte with its formula, not a retyped number. It must also keep calcium apart from calcium as CaCO3.
- EPA’s page for Method 6010D names axial or radial viewing of the plasma. If your ICP reads a metal both ways, each read should be its own analyte. Then you report the one your method calls for.
- If you run EPA 200.7 and SW-846 6010 samples in the same ICP run, the LIMS must judge each method’s QC from that one run.
- After a dirty sample, such as landfill leachate, an analyst may add extra **carryover** blanks. The run sequence must accept a blank anywhere, not only in fixed slots.
- An instrument results file can start with warm-up and tune rows that are not samples. The import must tell them from the real calibration blank by rule, not by name alone.

Sample to leachate

## What must a LIMS track for leaching tests?

A leaching test turns one sample into two. The LIMS has to keep both, and the link between them. Labs we talk to often say multi-step methods are the ones their LIMS handles worst.

- The leachate gets its own ID, linked to the parent sample and its chain of custody.
- The prep record keeps the percent solids, the fluid used and its pH check, and whether the phases were combined.
- Both clocks run for each analyte group: collection to extraction, then extraction to analysis.
- The extraction batch carries its QC. Method 1311 calls for at least one blank for every 20 extractions in a vessel. It calls for a matrix spike for each waste type and each analytical batch, added after filtering.
- Each result sits next to its level in 40 CFR 261.24, with a flag for any late hold time.
- The parent, the leachate, the QC and the result go out in one report your client can use.

Ask any vendor

- Show us a TCLP sample and its leachate, linked, on our own data.
- How do both hold-time clocks show on the bench list?
- Where do we record the fluid, the pH check and the percent solids?
- How do you count extraction blanks per 20 extractions?
- Show us hardness as a calculated analyte.
- Show us one ICP run reported under two methods.
- What does your import do with tune rows?

For how the sample’s record starts, see [chain of custody software for environmental labs](https://prismalims.com/chain-of-custody-software).

Our part

## How does Prisma LIMS support TCLP and SPLP?

Prisma LIMS supports TCLP and SPLP workflows, and we set them up for your lab. Prisma LIMS supports metals workflows from digestion batch to report.

One sample can carry two clocks: one to extraction and one to analysis. ICP axial and radial reads are kept as two analytes.

We import the CSV files your instruments or data systems export, with a column map set up for your lab. The import tells tune rows from calibration blanks by rules set for your lab.

Done-for-you means we do the work: we map your workflow, set up your methods and reports, move your data, test it with you in a sandbox, train your team on-site, and stay with you through go-live.

Accreditation belongs to the lab. Prisma LIMS keeps chain of custody and a full audit trail of who changed what and when.

You get a test system loaded with your own data in about 90 days. You run it next to your current process for an agreed side-by-side period, then we go live on your sign-off. Dates depend on how fast your team gives us methods and data.

Ask us to show it on your own methods and files. Comparing systems? Start with our [environmental LIMS guide](https://prismalims.com/environmental-lims).

Where we fit

## A TCLP record your client can use

Keep the leachate, its parent, both clocks and the extraction QC in one record, and the result holds up. Your client gets a report that shows how you reached the answer.

### Built for

Prisma LIMS is built only for environmental labs: mid-sized and large commercial, municipal and utility labs that test water, wastewater, drinking water, soil and sludge, in the US and Canada. Other environmental matrices are on request.

[Who Prisma LIMS is for](https://prismalims.com/who-its-for)

### Not a fit for

Prisma LIMS is not a fit for clinical-only or pharma-only labs, very small labs, or labs that prefer to build and run their own system.

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

## Frequently asked questions about TCLP and SPLP

What is TCLP used for?

TCLP is used to decide if a waste has the toxicity characteristic under 40 CFR 261.24. The lab leaches the waste, then tests the extract for the contaminants in Table 1. A result at or above a listed level makes the waste hazardous for that contaminant.

What does SPLP stand for?

SPLP stands for Synthetic Precipitation Leaching Procedure. It is EPA SW-846 Method 1312. It measures how easily organic and inorganic analytes move out of liquids, soils and wastes.

What is the difference between SPLP and TCLP?

The main difference is the fluid and the rule. TCLP uses acetic acid fluids and is the test named in 40 CFR 261.24. SPLP uses dilute sulfuric and nitric acid, or reagent water, and is not named in that rule. Both share the same hold-time table. For a side-by-side read, see [TCLP vs SPLP: what is the difference](https://prismalims.com/blog/tclp-vs-splp-what-is-the-difference).

What are the TCLP limits for metals?

The TCLP limits for metals, in mg/L, are arsenic 5.0, barium 100.0, cadmium 1.0 and chromium 5.0. Lead is 5.0, mercury 0.2, selenium 1.0 and silver 5.0. They come from 40 CFR 261.24 Table 1.

What is the TCLP limit for mercury?

The TCLP limit for mercury is 0.2 mg/L, EPA hazardous waste number D009, in 40 CFR 261.24 Table 1.

What is the TCLP 20 times rule?

It is a way to skip the TCLP extraction. Method 1311, section 1.2, says the TCLP need not be run if a total analysis shows the waste could not reach the regulatory levels. EPA explains that for a waste that is 100% solid, the lab may divide the total result by 20. That gives the most that could leach out, because the test uses 20 parts fluid to 1 part solid. If that value is below the level in 40 CFR 261.24, the leachate could not exceed it.

Can TCLP be run on liquids?

Yes. If a waste has less than 0.5% dry solids, the lab filters it, and the filtered liquid is the TCLP extract. No extraction step is needed for that liquid (Method 1311, 40 CFR 261.24).

How is a TCLP test performed?

A TCLP test checks the solids, sizes them, picks a fluid, tumbles the solid in fluid, filters the leachate, then tests it. The fluid is 20 times the weight of the solid, and the tumble lasts 18 ± 2 hours. See [the six steps](https://prismalims.com/tclp-splp-leaching#steps).

What are leaching tests used for?

Leaching tests show how much of a contaminant can move out of a waste, a soil or a liquid. TCLP decides the toxicity characteristic of a waste. SPLP looks at the same kind of mobility. For soils, its acid fluid depends on which side of the Mississippi River the site is on.

What should a lab with ICP and GC instruments look for in a LIMS?

Look for a LIMS that loads your instrument files without retyping and keeps QC per method. Ask it to handle calculated analytes, separate axial and radial reads, and extra blanks in a run. Ask every vendor to show it on your own files.

## Keep reading

- ### Sample holding times
  
  A late sample is a lost result. See common EPA hold times and the two clocks. Learn how a LIMS warns you in time.
  
  [EPA holding times and the LIMS clock](https://prismalims.com/sample-holding-times)
- ### Chain of custody
  
  A leachate is only as good as its parent sample’s record. See what a COC must hold. Learn how software keeps each hand-off.
  
  [Environmental chain of custody software](https://prismalims.com/chain-of-custody-software)
- ### PFAS testing
  
  PFAS work brings long analyte lists. See which EPA method fits which sample. Learn what a LIMS must hold.
  
  [PFAS testing LIMS guide](https://prismalims.com/pfas-testing-lims)
- ### Wastewater LIMS
  
  Some sludge goes to a leaching test. See what a wastewater lab needs from its software.
  
  [Wastewater lab software guide](https://prismalims.com/wastewater-lims)
- ### TCLP vs SPLP
  
  Two leaching tests, two fluids, two uses. A short read on how they differ.
  
  [TCLP vs SPLP: what is the difference](https://prismalims.com/blog/tclp-vs-splp-what-is-the-difference)

Last checked: 24 November 2026. Next check due: 24 May 2027.

## Schedule an online demo

The first call is a 30-minute Lab Systems Diagnostic. Then we show Prisma LIMS on your own files.

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

[contact@prismalims.com](mailto:contact@prismalims.com) [(224) 347-6794](tel:+12243476794)

[![](https://prismalims.com/hs-fs/hubfs/website%20assets/logos/prisma-lims-logo-1-line-white-340.webp?width=170&height=30&name=prisma-lims-logo-1-line-white-340.webp)](https://prismalims.com/)

A cloud LIMS built only for environmental labs in the US and Canada. Based in Illinois, US.

Book a call

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

Email or call

[contact@prismalims.com](mailto:contact@prismalims.com)

[(224) 347-6794](tel:+12243476794)

The first call is a 30-minute Lab Systems Diagnostic.

Company

- [Home](https://prismalims.com/)
- [How You Get Live](https://prismalims.com/how-it-works)
- [Pricing](https://prismalims.com/pricing)
- [Who It’s For](https://prismalims.com/who-its-for)
- [About Us](https://prismalims.com/about)
- [Blog](https://prismalims.com/blog)

Labs we serve

- [Environmental LIMS](https://prismalims.com/environmental-lims)
- [Commercial environmental labs](https://prismalims.com/commercial-lab-lims)
- [Municipal and treatment-plant labs](https://prismalims.com/municipal-lab-lims)

Sample types

- [Water LIMS](https://prismalims.com/who-its-for#water)
- [Wastewater LIMS](https://prismalims.com/wastewater-lims)
- [Drinking water LIMS](https://prismalims.com/drinking-water-lims)
- [Soil, sludge and biosolids](https://prismalims.com/soil-lims)

Guides

- [Cloud LIMS](https://prismalims.com/cloud-lims)
- [Chain of custody software](https://prismalims.com/chain-of-custody-software)
- [Sample holding times](https://prismalims.com/sample-holding-times)
- [TCLP and SPLP](https://prismalims.com/tclp-splp-leaching)
- [PFAS testing](https://prismalims.com/pfas-testing-lims)
- [NELAP and TNI records](https://prismalims.com/nelap-tni-lims-requirements)
- [LIMS cost over five years](https://prismalims.com/lims-total-cost-of-ownership)
- [Compare environmental LIMS vendors](https://prismalims.com/compare)

© 2026 Prisma LIMS. [Cookie Policy](https://prismalims.com/cookie-policy)

- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/linkedin-48.webp?width=24&height=24&name=linkedin-48.webp)](https://www.linkedin.com/company/prismalims/)
- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/youtube-48.webp?width=24&height=24&name=youtube-48.webp)](https://www.youtube.com/@PrismaLIMS)
- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/facebook-48.webp?width=24&height=24&name=facebook-48.webp)](https://www.facebook.com/prismalims/)
- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/instagram-48.webp?width=24&height=24&name=instagram-48.webp)](https://www.instagram.com/prismalims/)

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/#organization",
  "@type" : "Organization",
  "address" : {
    "@type" : "PostalAddress",
    "addressCountry" : "US",
    "addressRegion" : "IL"
  },
  "alternateName" : [ "PrismaLIMS", "LIMs-Plus" ],
  "areaServed" : [ {
    "@type" : "Country",
    "name" : "United States"
  }, {
    "@type" : "Country",
    "name" : "Canada"
  } ],
  "contactPoint" : {
    "@type" : "ContactPoint",
    "availableLanguage" : "English",
    "contactType" : "sales",
    "email" : "contact@prismalims.com",
    "telephone" : "+1-224-347-6794"
  },
  "description" : "Prisma LIMS is a cloud LIMS for environmental testing labs in the US and Canada. We set it up for your lab, move your data, train your team, and run the hosting and support.",
  "email" : "contact@prismalims.com",
  "founder" : {
    "@id" : "https://prismalims.com/about#dacian-florea",
    "@type" : "Person",
    "name" : "Dacian Florea",
    "sameAs" : [ "https://www.linkedin.com/in/dacian-florea/" ]
  },
  "foundingDate" : "2021",
  "knowsAbout" : [ "Laboratory information management systems", "Environmental laboratory software", "Cloud LIMS", "Wastewater testing", "Drinking water testing", "Soil and sludge testing", "Chain of custody", "Sample holding times", "TCLP and SPLP leaching", "PFAS testing methods", "TNI and NELAP accreditation records" ],
  "logo" : {
    "@id" : "https://prismalims.com/#logo",
    "@type" : "ImageObject",
    "caption" : "Prisma LIMS",
    "height" : 512,
    "url" : "https://48211686.fs1.hubspotusercontent-na1.net/hubfs/48211686/website%20assets/logos/prisma-lims-favicon-512.png",
    "width" : 512
  },
  "name" : "Prisma LIMS",
  "sameAs" : [ "https://www.linkedin.com/company/prismalims/", "https://www.youtube.com/@PrismaLIMS", "https://www.facebook.com/prismalims/", "https://www.instagram.com/prismalims/" ],
  "telephone" : "+1-224-347-6794",
  "url" : "https://prismalims.com/"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/#website",
  "@type" : "WebSite",
  "alternateName" : [ "PrismaLIMS", "LIMs-Plus" ],
  "inLanguage" : "en-US",
  "name" : "Prisma LIMS",
  "publisher" : {
    "@id" : "https://prismalims.com/#organization"
  },
  "url" : "https://prismalims.com/"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/tclp-splp-leaching#webpage",
  "@type" : "WebPage",
  "about" : [ {
    "@id" : "https://prismalims.com/#organization"
  }, {
    "@id" : "https://prismalims.com/tclp-splp-leaching#term-tclp"
  }, {
    "@id" : "https://prismalims.com/tclp-splp-leaching#term-splp"
  } ],
  "breadcrumb" : {
    "@id" : "https://prismalims.com/tclp-splp-leaching#breadcrumb"
  },
  "dateModified" : "2026-11-26",
  "description" : "TCLP and SPLP in plain words: what each leaching test is for, the steps, the two hold-time clocks, and what a LIMS must track from sample to leachate.",
  "inLanguage" : "en-US",
  "isPartOf" : {
    "@id" : "https://prismalims.com/#website"
  },
  "mainEntity" : {
    "@id" : "https://prismalims.com/tclp-splp-leaching#article"
  },
  "name" : "TCLP Test and SPLP: Steps, Limits, Hold Times - Prisma LIMS",
  "url" : "https://prismalims.com/tclp-splp-leaching"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/tclp-splp-leaching#article",
  "@type" : "Article",
  "author" : {
    "@id" : "https://prismalims.com/#organization",
    "@type" : "Organization",
    "name" : "Prisma LIMS"
  },
  "dateModified" : "2026-11-26",
  "datePublished" : "2026-11-24",
  "headline" : "TCLP test and SPLP: what your LIMS must track",
  "image" : "https://48211686.fs1.hubspotusercontent-na1.net/hubfs/48211686/website%20assets/images/featured%20images/og-tclp-splp-leaching.jpg",
  "inLanguage" : "en-US",
  "mainEntityOfPage" : {
    "@id" : "https://prismalims.com/tclp-splp-leaching#webpage"
  },
  "publisher" : {
    "@id" : "https://prismalims.com/#organization"
  }
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/tclp-splp-leaching#breadcrumb",
  "@type" : "BreadcrumbList",
  "itemListElement" : [ {
    "@type" : "ListItem",
    "item" : "https://prismalims.com/",
    "name" : "Home",
    "position" : 1
  }, {
    "@type" : "ListItem",
    "item" : "https://prismalims.com/environmental-lims",
    "name" : "Environmental LIMS",
    "position" : 2
  }, {
    "@type" : "ListItem",
    "item" : "https://prismalims.com/tclp-splp-leaching",
    "name" : "TCLP and SPLP",
    "position" : 3
  } ]
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/tclp-splp-leaching#terms",
  "@type" : "DefinedTermSet",
  "hasDefinedTerm" : [ {
    "@id" : "https://prismalims.com/tclp-splp-leaching#term-tclp",
    "@type" : "DefinedTerm",
    "alternateName" : "Toxicity Characteristic Leaching Procedure",
    "description" : "TCLP (EPA SW-846 Method 1311) is a lab test that measures how easily contaminants move out of a waste. Under 40 CFR 261.24, its result decides whether the waste has the toxicity characteristic.",
    "inDefinedTermSet" : {
      "@id" : "https://prismalims.com/tclp-splp-leaching#terms"
    },
    "name" : "TCLP",
    "url" : "https://prismalims.com/tclp-splp-leaching#what"
  }, {
    "@id" : "https://prismalims.com/tclp-splp-leaching#term-splp",
    "@type" : "DefinedTerm",
    "alternateName" : "Synthetic Precipitation Leaching Procedure",
    "description" : "SPLP (Method 1312) is a similar test for liquids, soils and wastes.",
    "inDefinedTermSet" : {
      "@id" : "https://prismalims.com/tclp-splp-leaching#terms"
    },
    "name" : "SPLP",
    "url" : "https://prismalims.com/tclp-splp-leaching#what"
  } ],
  "name" : "TCLP and SPLP terms"
}
```