---
title: Soil LIMS for Soil, Sludge and Biosolids Labs - Prisma LIMS
description: "What a soil, sludge and biosolids lab needs from its LIMS: dry-weight results, two hold-time clocks, digestion batches, TCLP and SPLP, and Part 503 metals."
image: https://prismalims.com/hubfs/website%20assets/images/featured%20images/og-soil-lims.jpg
---

[Skip to content](https://prismalims.com/soil-lims#main)

[![Prisma LIMS](https://prismalims.com/hs-fs/hubfs/website%20assets/logos/prisma-lims-logo-1-line-340.webp?width=170&height=30&name=prisma-lims-logo-1-line-340.webp)](https://prismalims.com/) [Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

- [Home](https://prismalims.com/)
- [How You Get Live](https://prismalims.com/how-it-works)
- [Who It’s For](https://prismalims.com/who-its-for)
- Labs we serve
  
    - [Environmental LIMS](https://prismalims.com/environmental-lims)
    - By sample type 
          - [Water LIMS](https://prismalims.com/who-its-for#water)
          - [Wastewater LIMS](https://prismalims.com/wastewater-lims)
          - [Drinking water LIMS](https://prismalims.com/drinking-water-lims)
          - [Soil, sludge and biosolids](https://prismalims.com/soil-lims)
    - By lab type 
          - [Commercial environmental labs](https://prismalims.com/commercial-lab-lims)
          - [Municipal and treatment-plant labs](https://prismalims.com/municipal-lab-lims)
- Guides
  
    - [Cloud LIMS](https://prismalims.com/cloud-lims)
    - [Chain of custody software](https://prismalims.com/chain-of-custody-software)
    - [Sample holding times](https://prismalims.com/sample-holding-times)
    - [TCLP and SPLP](https://prismalims.com/tclp-splp-leaching)
    - [PFAS testing](https://prismalims.com/pfas-testing-lims)
    - [NELAP and TNI records](https://prismalims.com/nelap-tni-lims-requirements)
    - [LIMS cost over five years](https://prismalims.com/lims-total-cost-of-ownership)
    - [Compare environmental LIMS vendors](https://prismalims.com/compare)
    - [Blog](https://prismalims.com/blog)
- [About Us](https://prismalims.com/about)

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

1. [Home](https://prismalims.com/)
2. [Environmental LIMS](https://prismalims.com/environmental-lims)
3. Soil, sludge and biosolids

For environmental soil, sludge and biosolids labs

# Soil LIMS: what a soil, sludge and biosolids lab needs from its software

Monday morning, two coolers sit at receiving: soil cores from a cleanup site and sludge jars from a plant’s digester. Before a metals result can go on a biosolids report, the lab needs each jar’s percent solids. Part 503 states its metal concentration limits on a dry weight basis (40 CFR 503.13). This guide is for the lab managers, section leads and QA staff who handle both.

By the Prisma LIMS team · Updated 26 November 2026

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea) [What a soil LIMS must handle](https://prismalims.com/soil-lims#handle)

In short

A soil LIMS is software that tracks environmental soil, sediment, sludge and biosolids samples from the chain of custody to the report. For metals, organics and leaching tests, it keeps each sample’s percent solids and reports results on a dry weight basis. It runs each hold-time clock and ties every result to its prep batch and QC. Prisma LIMS is a cloud LIMS built only for environmental labs, and we set it up for your lab.

Environmental soil, not soil fertility

This page is about environmental testing: soil, sediment, sludge, biosolids and waste, tested for cleanup sites, permits, waste rules and land application. It is not about soil-fertility work or fertilizer recommendations.

On this page

1. [Why a soil result has to hold up](https://prismalims.com/soil-lims#why)
2. [What a soil and sludge lab does all day](https://prismalims.com/soil-lims#what)
3. [What a soil LIMS must handle](https://prismalims.com/soil-lims#handle)
4. [What a biosolids lab tracks](https://prismalims.com/soil-lims#biosolids)
5. [Where Prisma LIMS fits](https://prismalims.com/soil-lims#fit)
6. [Questions soil and biosolids labs ask](https://prismalims.com/soil-lims#questions)

Why it matters

## Why does a soil or sludge result have to hold up?

A soil or sludge result often decides something big. A cleanup site stays open or closes. A waste goes to one landfill or another. A load of biosolids goes to a field, or it doesn’t.

So the number has to trace back to the sample, the prep batch, the QC and the person who signed it. If the percent solids is wrong, every dry-weight result on that sample is wrong too.

EPA’s Region 8 biosolids handbook says every result on a biosolids report must be on a dry weight basis. It also lists what the report must show: the methods, the dates and times of analysis, the analyst and the chain of custody forms.

Your fields of accreditation decide which results you may report. See [NELAP and TNI records: what to check in a LIMS](https://prismalims.com/nelap-tni-lims-requirements).

The daily work

## What does a soil and sludge lab do all day?

The work runs in the same order every day, from the cooler to the report.

- Jars and bags arrive in coolers with a chain of custody (COC). Sample control checks the temperature and logs each container. See [what chain of custody software must record](https://prismalims.com/chain-of-custody-software).
- For percent solids, the lab weighs a portion, dries it and weighs it again. Then results can be reported on a dry weight basis.
- Metals samples are digested and organics samples are extracted. Each prep batch carries its own QC.
- Some samples go to a leaching test, such as TCLP or SPLP. One sample becomes two: the solid and its leachate.
- Results come off the instrument, get checked against the QC, and are signed out.
- Then come the reports: a dry-weight report, a leachate report, and often a client EDD file.

### What is dry weight?

Dry weight means the result is given per kilogram of dry solids, not per kilogram of the wet sample. Part 503 defines the dry weight basis as “dried at 105 degrees Celsius until reaching a constant mass” (40 CFR 503.9).

To get it, the lab divides the as-received result by the fraction of solids. At 25% solids, a result of 30 mg/kg as received is 120 mg/kg dry weight.

The reporting limit scales the same way. A reporting limit of 0.5 mg/kg as received becomes 2 mg/kg dry weight at 25% solids.

What to check

## What must a soil LIMS handle?

Five jobs. Each ends with a question to ask any vendor. Biosolids get their own section below.

### Percent solids and dry-weight results

Each sample reported on a dry weight basis needs its percent solids on record, tied to the results it changes. The math must run the same way every time, for the result and for its reporting limit. Nobody should redo it in a spreadsheet.

For biosolids, Part 503 names the method for total, fixed and volatile solids: Standard Methods 2540 G (40 CFR 503.8).

Prisma LIMS reports dry-weight results with the reporting limit scaled.

Ask any vendor, including us

- Show us a dry-weight result with its reporting limit scaled.

### Two hold-time clocks

Many soil tests have two clocks. Take semivolatile organics in soil, sediment or sludge. EPA’s SW-846 guidance gives them 14 days to extraction, then 40 days to analyze the extract (SW-846 Chapter Four, Table 4-1).

SW-846 times are guidance, not a rule. Your project plan or your state sets which times apply. See our [sample holding times table](https://prismalims.com/sample-holding-times) for more tests.

Clock one: collection to extraction

Clock two: extraction to analysis

Semivolatile organics in soil under SW-846 guidance: 14 days from collection to extraction, then 40 days from extraction to analysis (SW-846 Chapter Four).

Prisma LIMS tracks each sample’s hold time from the collection time, shows the time left and warns you before it runs out. One sample can carry two clocks: one to extraction and one to analysis.

Ask any vendor, including us

- Log a sample that needs extraction, and show us both of its clocks.

### Digestion and prep batches with QC

A metals sample is digested before it reaches the ICP. SW-846 Method 3050B gives “two separate digestion procedures for sediments, sludges, and soils” (Method 3050B).

The digestion batch carries its QC, such as a method blank, a lab control sample and a matrix spike. That QC has to follow every result from that batch to the report.

Prisma LIMS runs analytical and prep batches with QC. Prisma LIMS supports metals workflows from digestion batch to report.

Ask any vendor, including us

- Show us a digestion batch, its QC, and one result on the final report that points back to it.

### Leaching tests: TCLP and SPLP

A leaching test adds a step. The lab tracks the solid, the leachate and the clocks for both. TCLP is SW-846 Method 1311 and SPLP is Method 1312 (Method 1311, Method 1312).

For metals other than mercury, TCLP allows 180 days to the extraction and 180 more days to analysis (Method 1311). See [what a LIMS must track for TCLP and SPLP](https://prismalims.com/tclp-splp-leaching).

Prisma LIMS supports TCLP and SPLP workflows, and we set them up for your lab.

Ask any vendor, including us

- Walk us through a TCLP or SPLP leachate workflow.

### PFAS in soil and biosolids

EPA Method 1633A covers 40 PFAS in wastewater, soil, biosolids, sediment and more (Method 1633A). Each sample type has its own prep.

Prisma LIMS supports PFAS workflows for Methods 1633/1633A, 533 and 537.1: analyte lists, batch QC and blanks. See [PFAS testing and Method 1633A](https://prismalims.com/pfas-testing-lims).

Ask any vendor

- Show us a 1633A batch on a soil sample, with its blanks.

Part 503

## What does a biosolids lab track for land application?

EPA uses “biosolids” for sewage sludge treated to meet its rules, to be applied to land as a soil conditioner or fertilizer. The federal rule is 40 CFR Part 503. It sets pollutant limits, pathogen and vector attraction reduction, monitoring, recordkeeping and reporting. For the lab, that means metals on a dry weight basis, pathogen classes and a testing schedule set by how much the plant applies.

### Metals on a dry weight basis

Part 503 judges metals on a dry weight basis. Table 3 gives dry-weight monthly average concentrations for certain land-application pathways. Section 503.13 also sets ceiling and loading limits (40 CFR 503.13). Labs analyze metals by the SW-846 methods the rule names (40 CFR 503.8).

| Metal | Monthly average limit (mg/kg, dry weight) | Source |
| --- | --- | --- |
| Arsenic | 41 | 40 CFR 503.13, Table 3 |
| Cadmium | 39 | 40 CFR 503.13, Table 3 |
| Copper | 1,500 | 40 CFR 503.13, Table 3 |
| Lead | 300 | 40 CFR 503.13, Table 3 |
| Mercury | 17 | 40 CFR 503.13, Table 3 |
| Nickel | 420 | 40 CFR 503.13, Table 3 |
| Selenium | 100 | 40 CFR 503.13, Table 3 |
| Zinc | 2,800 | 40 CFR 503.13, Table 3 |

### How often a plant tests

The rule ties testing to how much biosolids a plant applies in a 365-day period, in dry metric tons. The same schedule covers metals, pathogens and some vector attraction options.

| Dry metric tons per 365 days | How often to monitor | Source |
| --- | --- | --- |
| More than 0, under 290 | Once a year | 40 CFR 503.16, Table 1 |
| 290 to under 1,500 | Once a quarter (4 times a year) | 40 CFR 503.16, Table 1 |
| 1,500 to under 15,000 | Once every 60 days (6 times a year) | 40 CFR 503.16, Table 1 |
| 15,000 or more | Once a month (12 times a year) | 40 CFR 503.16, Table 1 |

### Pathogens and vector attraction

Part 503 sets two pathogen classes. For Class A, fecal coliform must be below 1,000 MPN per gram of total solids, or Salmonella below 3 MPN per 4 grams. Class A also requires meeting one of the alternatives in §503.32(a), such as a time and temperature treatment.

One way to show Class B is to collect seven samples. Their geometric mean fecal coliform must be below 2,000,000 MPN or CFU per gram of total solids.

Each count is on a dry weight basis, so the pathogen result needs a solids result too. Part 503 lists 12 vector attraction options, and land-applied biosolids use one of the first 10, such as a 38% cut in volatile solids.

### Who does the testing, and which rules apply

EPA’s handbook expects most treatment plants to send this testing to a commercial lab. Many larger plants run part of it in their own lab. See [LIMS for municipal and water utility labs](https://prismalims.com/municipal-lab-lims) and [what a wastewater LIMS must handle](https://prismalims.com/wastewater-lims).

States can add rules of their own. EPA has authorized nine states to run the biosolids program. Washington, for one, lists the methods labs must use for biosolids unless its ecology department says otherwise.

### Where Prisma LIMS fits in biosolids work

Prisma LIMS reports dry-weight results with the reporting limit scaled, and runs metals from digestion batch to report. Ask us to show it on your own biosolids samples.

Ask any vendor

- Show us a biosolids sample with its metals on a dry weight basis, next to the Part 503 limits.
- For Class B, how does the system keep seven samples together for the geometric mean?

Where we fit

## Where Prisma LIMS fits, and where it does not

Prisma LIMS is a cloud LIMS for environmental testing labs in the US and Canada. We set it up for your lab, move your data, train your team, and run the hosting and support.

Prisma LIMS supports soil and sludge lab workflows: two hold-time clocks per sample, and analytical and prep batches with QC. It reports dry-weight results with the reporting limit scaled, runs metals from digestion batch to report, and handles TCLP and SPLP leachate workflows.

We import the CSV files your instruments or data systems export, with a column map set up for your lab. Ask us to show it on your own methods and files.

Methods running on Prisma LIMS today: EPA 524, 525 and 552, and THMs; EPA 200.7 and 200.8, and SW-846 6010 and 6020; total coliform and E. coli; BOD and TSS.

Done-for-you means we do the work: we map your workflow, set up your methods and reports, move your data, test it with you in a sandbox, train your team on-site, and stay with you through go-live.

Accreditation belongs to the lab. Prisma LIMS keeps chain of custody and a full audit trail of who changed what and when.

### Built for

Prisma LIMS is built only for environmental labs: mid-sized and large commercial, municipal and utility labs that test water, wastewater, drinking water, soil and sludge, in the US and Canada. Other environmental matrices are on request.

[Who Prisma LIMS is for](https://prismalims.com/who-its-for)

### Not a fit for

Prisma LIMS is not a fit for clinical-only or pharma-only labs, very small labs, or labs that prefer to build and run their own system.

### What it costs

Setup is a one-time fee. After go-live there is one monthly fee that covers hosting, updates, support and every user. We give you a range on our first call and a written quote for your lab.

[How LIMS pricing works](https://prismalims.com/lims-total-cost-of-ownership#pricing-models)

### How you get live

You get a test system loaded with your own data in about 90 days. You run it next to your current process for an agreed side-by-side period, then we go live on your sign-off. Dates depend on how fast your team gives us methods and data.

[How you get live](https://prismalims.com/how-it-works)

Back to the result

## A solids result you can trace

Keep each sample’s percent solids, clocks, prep batch and QC in one record. Then the dry-weight number on the report traces back to the bench. That is what holds up when a client, a state or an assessor asks.

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

## Questions soil and biosolids labs ask

What is a soil LIMS?

A soil LIMS is a laboratory information management system for labs that test soil, sediment, sludge and biosolids. It logs each sample and its chain of custody, keeps percent solids and runs the hold-time clocks. It also builds prep batches with QC and puts out dry-weight reports and client files.

What does dry weight mean in a lab report?

The result is given per kilogram of dry solids, not of the wet sample. The lab divides the as-received result by the fraction of solids. At 25% solids, 30 mg/kg as received is 120 mg/kg dry weight. The reporting limit scales the same way (40 CFR 503.9).

Do soil samples have hold times?

Yes. EPA’s SW-846 guidance lists hold times for solids. Semivolatile organics in soil, for example, have 14 days to extraction and 40 days from extraction to analysis (SW-846 Chapter Four). Your project plan or your state decides which times apply.

What does Part 503 require a lab to test?

Part 503 sets ceiling, loading and concentration limits for metals in biosolids, on a dry weight basis (503.13). It also sets pathogen classes A and B (503.32) and vector attraction reduction (503.33). Labs must use the methods it names or those in 40 CFR 136 (503.8). How often a plant tests depends on how much it applies in a year (503.16).

What is the difference between Class A and Class B biosolids?

Class A biosolids meet the strictest pathogen limits. Fecal coliform must be below 1,000 MPN per gram of total solids, or Salmonella below 3 MPN per 4 grams. The plant must also meet one of the Class A alternatives. Class B allows more. One way to show it is a geometric mean below 2,000,000 per gram across seven samples. Both are counted on a dry weight basis (40 CFR 503.32).

Can one LIMS handle water and soil?

It should. Many environmental labs test water, soil and sludge under one roof. The same sample login, hold-time clocks, batch QC and audit trail apply. Solids add percent solids and dry-weight reporting. Prisma LIMS is built only for environmental labs that test water, wastewater, drinking water, soil and sludge.

## Keep reading

- ### TCLP and SPLP
  
  A leaching test turns one sample into two. See the steps, the metals limits and the clocks for each.
  
  [TCLP and SPLP: what a LIMS must track](https://prismalims.com/tclp-splp-leaching)
- ### Sample holding times
  
  One missed clock costs a resample. See common EPA hold times with sources, and how a LIMS keeps the clock.
  
  [Sample holding times and how a LIMS tracks them](https://prismalims.com/sample-holding-times)
- ### PFAS testing
  
  Method 1633A covers soil, sediment and biosolids. See which EPA method fits which sample.
  
  [PFAS testing and Method 1633A](https://prismalims.com/pfas-testing-lims)
- ### Wastewater LIMS
  
  Biosolids start at the treatment plant. See what a wastewater lab needs for its permit reports.
  
  [What a wastewater LIMS must handle](https://prismalims.com/wastewater-lims)
- ### Environmental LIMS guide
  
  A wrong choice costs years. This guide lists what to check in any system, and the questions to ask.
  
  [How to choose an environmental LIMS](https://prismalims.com/environmental-lims)

Last checked: 26 November 2026. Next check due: 26 May 2027.

## Schedule an online demo

The first call is a 30-minute Lab Systems Diagnostic. Then we show Prisma LIMS on your own files.

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

[contact@prismalims.com](mailto:contact@prismalims.com) [(224) 347-6794](tel:+12243476794)

[![](https://prismalims.com/hs-fs/hubfs/website%20assets/logos/prisma-lims-logo-1-line-white-340.webp?width=170&height=30&name=prisma-lims-logo-1-line-white-340.webp)](https://prismalims.com/)

A cloud LIMS built only for environmental labs in the US and Canada. Based in Illinois, US.

Book a call

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

Email or call

[contact@prismalims.com](mailto:contact@prismalims.com)

[(224) 347-6794](tel:+12243476794)

The first call is a 30-minute Lab Systems Diagnostic.

Company

- [Home](https://prismalims.com/)
- [How You Get Live](https://prismalims.com/how-it-works)
- [Pricing](https://prismalims.com/pricing)
- [Who It’s For](https://prismalims.com/who-its-for)
- [About Us](https://prismalims.com/about)
- [Blog](https://prismalims.com/blog)

Labs we serve

- [Environmental LIMS](https://prismalims.com/environmental-lims)
- [Commercial environmental labs](https://prismalims.com/commercial-lab-lims)
- [Municipal and treatment-plant labs](https://prismalims.com/municipal-lab-lims)

Sample types

- [Water LIMS](https://prismalims.com/who-its-for#water)
- [Wastewater LIMS](https://prismalims.com/wastewater-lims)
- [Drinking water LIMS](https://prismalims.com/drinking-water-lims)
- [Soil, sludge and biosolids](https://prismalims.com/soil-lims)

Guides

- [Cloud LIMS](https://prismalims.com/cloud-lims)
- [Chain of custody software](https://prismalims.com/chain-of-custody-software)
- [Sample holding times](https://prismalims.com/sample-holding-times)
- [TCLP and SPLP](https://prismalims.com/tclp-splp-leaching)
- [PFAS testing](https://prismalims.com/pfas-testing-lims)
- [NELAP and TNI records](https://prismalims.com/nelap-tni-lims-requirements)
- [LIMS cost over five years](https://prismalims.com/lims-total-cost-of-ownership)
- [Compare environmental LIMS vendors](https://prismalims.com/compare)

© 2026 Prisma LIMS. [Cookie Policy](https://prismalims.com/cookie-policy)

- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/linkedin-48.webp?width=24&height=24&name=linkedin-48.webp)](https://www.linkedin.com/company/prismalims/)
- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/youtube-48.webp?width=24&height=24&name=youtube-48.webp)](https://www.youtube.com/@PrismaLIMS)
- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/facebook-48.webp?width=24&height=24&name=facebook-48.webp)](https://www.facebook.com/prismalims/)
- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/instagram-48.webp?width=24&height=24&name=instagram-48.webp)](https://www.instagram.com/prismalims/)

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/#organization",
  "@type" : "Organization",
  "address" : {
    "@type" : "PostalAddress",
    "addressCountry" : "US",
    "addressRegion" : "IL"
  },
  "alternateName" : [ "PrismaLIMS", "LIMs-Plus" ],
  "areaServed" : [ {
    "@type" : "Country",
    "name" : "United States"
  }, {
    "@type" : "Country",
    "name" : "Canada"
  } ],
  "contactPoint" : {
    "@type" : "ContactPoint",
    "availableLanguage" : "English",
    "contactType" : "sales",
    "email" : "contact@prismalims.com",
    "telephone" : "+1-224-347-6794"
  },
  "description" : "Prisma LIMS is a cloud LIMS for environmental testing labs in the US and Canada. We set it up for your lab, move your data, train your team, and run the hosting and support.",
  "email" : "contact@prismalims.com",
  "founder" : {
    "@id" : "https://prismalims.com/about#dacian-florea",
    "@type" : "Person",
    "name" : "Dacian Florea",
    "sameAs" : [ "https://www.linkedin.com/in/dacian-florea/" ]
  },
  "foundingDate" : "2021",
  "knowsAbout" : [ "Laboratory information management systems", "Environmental laboratory software", "Cloud LIMS", "Wastewater testing", "Drinking water testing", "Soil and sludge testing", "Chain of custody", "Sample holding times", "TCLP and SPLP leaching", "PFAS testing methods", "TNI and NELAP accreditation records" ],
  "logo" : {
    "@id" : "https://prismalims.com/#logo",
    "@type" : "ImageObject",
    "caption" : "Prisma LIMS",
    "height" : 512,
    "url" : "https://48211686.fs1.hubspotusercontent-na1.net/hubfs/48211686/website%20assets/logos/prisma-lims-favicon-512.png",
    "width" : 512
  },
  "name" : "Prisma LIMS",
  "sameAs" : [ "https://www.linkedin.com/company/prismalims/", "https://www.youtube.com/@PrismaLIMS", "https://www.facebook.com/prismalims/", "https://www.instagram.com/prismalims/" ],
  "telephone" : "+1-224-347-6794",
  "url" : "https://prismalims.com/"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/#website",
  "@type" : "WebSite",
  "alternateName" : [ "PrismaLIMS", "LIMs-Plus" ],
  "inLanguage" : "en-US",
  "name" : "Prisma LIMS",
  "publisher" : {
    "@id" : "https://prismalims.com/#organization"
  },
  "url" : "https://prismalims.com/"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/soil-lims#webpage",
  "@type" : "WebPage",
  "about" : {
    "@id" : "https://prismalims.com/#organization"
  },
  "breadcrumb" : {
    "@id" : "https://prismalims.com/soil-lims#breadcrumb"
  },
  "dateModified" : "2026-11-26",
  "description" : "What a soil, sludge and biosolids lab needs from its LIMS: dry-weight results, two hold-time clocks, digestion batches, TCLP and SPLP, and Part 503 metals.",
  "inLanguage" : "en-US",
  "isPartOf" : {
    "@id" : "https://prismalims.com/#website"
  },
  "mainEntity" : {
    "@id" : "https://prismalims.com/soil-lims#article"
  },
  "name" : "Soil LIMS for Soil, Sludge and Biosolids Labs - Prisma LIMS",
  "url" : "https://prismalims.com/soil-lims"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/soil-lims#article",
  "@type" : "Article",
  "author" : {
    "@id" : "https://prismalims.com/#organization",
    "@type" : "Organization",
    "name" : "Prisma LIMS"
  },
  "dateModified" : "2026-11-26",
  "datePublished" : "2026-11-26",
  "headline" : "Soil LIMS: what a soil, sludge and biosolids lab needs from its software",
  "image" : "https://48211686.fs1.hubspotusercontent-na1.net/hubfs/48211686/website%20assets/images/featured%20images/og-soil-lims.jpg",
  "inLanguage" : "en-US",
  "mainEntityOfPage" : {
    "@id" : "https://prismalims.com/soil-lims#webpage"
  },
  "publisher" : {
    "@id" : "https://prismalims.com/#organization"
  }
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/soil-lims#breadcrumb",
  "@type" : "BreadcrumbList",
  "itemListElement" : [ {
    "@type" : "ListItem",
    "item" : "https://prismalims.com/",
    "name" : "Home",
    "position" : 1
  }, {
    "@type" : "ListItem",
    "item" : "https://prismalims.com/environmental-lims",
    "name" : "Environmental LIMS",
    "position" : 2
  }, {
    "@type" : "ListItem",
    "item" : "https://prismalims.com/soil-lims",
    "name" : "Soil, sludge and biosolids",
    "position" : 3
  } ]
}
```