---
title: Drinking Water LIMS for Certified Labs - Prisma LIMS
description: "What a certified drinking water lab needs from its LIMS: short hold times, batch QC, state files such as CMDP, UCMR, PFAS methods and SDWIS explained."
image: https://prismalims.com/hubfs/website%20assets/images/featured%20images/og-drinking-water-lims.jpg
---

[Skip to content](https://prismalims.com/drinking-water-lims#main)

[![Prisma LIMS](https://prismalims.com/hs-fs/hubfs/website%20assets/logos/prisma-lims-logo-1-line-340.webp?width=170&height=30&name=prisma-lims-logo-1-line-340.webp)](https://prismalims.com/) [Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

- [Home](https://prismalims.com/)
- [How You Get Live](https://prismalims.com/how-it-works)
- [Who It’s For](https://prismalims.com/who-its-for)
- Labs we serve
  
    - [Environmental LIMS](https://prismalims.com/environmental-lims)
    - By sample type 
          - [Water LIMS](https://prismalims.com/who-its-for#water)
          - [Wastewater LIMS](https://prismalims.com/wastewater-lims)
          - [Drinking water LIMS](https://prismalims.com/drinking-water-lims)
          - [Soil, sludge and biosolids](https://prismalims.com/soil-lims)
    - By lab type 
          - [Commercial environmental labs](https://prismalims.com/commercial-lab-lims)
          - [Municipal and treatment-plant labs](https://prismalims.com/municipal-lab-lims)
- Guides
  
    - [Cloud LIMS](https://prismalims.com/cloud-lims)
    - [Chain of custody software](https://prismalims.com/chain-of-custody-software)
    - [Sample holding times](https://prismalims.com/sample-holding-times)
    - [TCLP and SPLP](https://prismalims.com/tclp-splp-leaching)
    - [PFAS testing](https://prismalims.com/pfas-testing-lims)
    - [NELAP and TNI records](https://prismalims.com/nelap-tni-lims-requirements)
    - [LIMS cost over five years](https://prismalims.com/lims-total-cost-of-ownership)
    - [Compare environmental LIMS vendors](https://prismalims.com/compare)
    - [Blog](https://prismalims.com/blog)
- [About Us](https://prismalims.com/about)

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

1. [Home](https://prismalims.com/)
2. [Environmental LIMS](https://prismalims.com/environmental-lims)
3. Drinking water LIMS

For certified drinking water labs

# Drinking water LIMS: what a certified drinking water lab needs

A drinking water LIMS tracks compliance samples from the water system’s schedule to the result the state receives. A total coliform sample from a distribution site is collected at 9 a.m. on a Saturday. It must start incubation within 30 hours of collection (40 CFR 141.852), so someone sets it up by 3 p.m. on Sunday. This guide is for lab directors and QA managers at certified drinking water labs. It covers what drinking water lab software must handle: the coliform clock, batch QC, state reporting, UCMR and the PFAS methods. Use it to judge any drinking water testing lab software, ours included.

By the Prisma LIMS team · Updated 26 November 2026

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea) [See the six steps](https://prismalims.com/drinking-water-lims#how)

In short

A drinking water LIMS tracks compliance samples from the water system’s schedule to the result the state receives. It handles short hold times, such as 30 hours from collection to incubation for coliform (40 CFR 141.852), batches with QC, and the state’s file format. Accreditation belongs to the lab; the software keeps the record. Prisma LIMS is a cloud LIMS built only for environmental labs in the US and Canada, and we set it up for your lab.

On this page

1. [Why a late result hurts](https://prismalims.com/drinking-water-lims#why)
2. [What the lab reports](https://prismalims.com/drinking-water-lims#what)
3. [How the work flows](https://prismalims.com/drinking-water-lims#how)
4. [PFAS: Methods 533 and 537.1](https://prismalims.com/drinking-water-lims#pfas)
5. [What to ask any vendor](https://prismalims.com/drinking-water-lims#ask)
6. [Where Prisma LIMS fits](https://prismalims.com/drinking-water-lims#fit)
7. [Questions labs ask](https://prismalims.com/drinking-water-lims#questions)

Why it matters

## Why a late result is the water system’s problem too

A public water system has to sample on a schedule and report on time. States report each system’s violations to EPA. One kind on that list is a system that “failed to follow established monitoring and reporting schedules”.

So a missed bacteria hold time is more than a lost result. It means a new sample, a call to your client and a late report. A typo in a state upload means a fix and a second upload. Each one costs a day your team does not have.

Good drinking water lab software is there to stop both. The goal is fewer entry errors, fewer missed hold times, and more samples through the same team.

What to track

## What does a certified drinking water lab report?

A drinking water lab tests compliance samples for public water systems. With a few exceptions, such as pH and turbidity, those results only count if a lab certified by EPA or the state ran them (40 CFR 141.28). Under the Revised Total Coliform Rule, the lab must be certified for each method it uses for that work (40 CFR 141.852).

The water system owns the schedule. The lab runs the tests and sends the results. Labs and utilities can report to the state electronically, for example through CMDP.

### SDWIS and CMDP in plain words

**SDWIS** is the Safe Drinking Water Information System. The Safe Drinking Water Act requires states to report drinking water information to EPA. EPA keeps it in a federal database, the SDWIS Fed Data Warehouse. It holds each water system’s basic details, its violations and the enforcement actions taken.

**CMDP** is EPA’s Compliance Monitoring Data Portal. Drinking water utilities and labs use it to report data electronically to the state, with fewer errors. It adds no new reporting: labs report the same data on the schedule the rules already set.

Your state is the primacy agency. It decides how it takes lab data and in what file. Check its current rules before you choose a LIMS.

### UCMR 6: where it stands

UCMR is the Unregulated Contaminant Monitoring Rule. The Safe Drinking Water Act has EPA issue a new list once every five years. It names unregulated contaminants for public water systems to monitor.

**UCMR 6 is still a proposed rule.** EPA proposed it on July 1, 2026. As proposed, water systems would sample for 30 chemical contaminants, from January 2028 through December 2030, with EPA methods. The list includes ultrashort organofluorine compounds, among them certain PFAS.

EPA runs an approval program for labs that want to analyze UCMR samples. A proposed rule can change, so check the EPA page before you plan for it.

### Certification and accreditation: two different programs

State drinking water lab certification and NELAP accreditation are not the same thing. Each has its own rules and its own audits. Which ones your lab needs depends on your state and your work.

| Program | What it is | Who runs it |
| --- | --- | --- |
| State drinking water lab certification (Safe Drinking Water Act) | Lets a lab analyze drinking water compliance samples. The lab must use approved methods, pass proficiency testing (PT) samples at least annually for each method and analyte, and pass on-site audits. | EPA or the state. |
| NELAP accreditation (The NELAC Institute, TNI) | The National Environmental Laboratory Accreditation Program. It accredits environmental labs to the TNI standard. | State agencies act as the accreditation bodies. Each state picks which EPA programs it covers, from drinking water only to all of them. |

Which program applies is the lab’s call, and the lab holds the certificate. What Prisma LIMS keeps for the auditor is under [where Prisma LIMS fits](https://prismalims.com/drinking-water-lims#fit).

A clean record from the field to the report is what an auditor reads. More in our guide to [environmental chain of custody software](https://prismalims.com/chain-of-custody-software).

Step by step

## How a drinking water LIMS handles the work

Here is the path of one compliance sample, and what the LIMS has to keep at each step.

1. 1
   
   ### The water system’s sample schedule
   
   The LIMS holds each client’s sites and the samples due. Your staff see what is due before any bottle goes out.
2. 2
   
   ### Bottle kits and pre-login
   
   The right bottles go out for each site. For coliform samples from chlorinated water, sodium thiosulfate goes in the bottle before it is sterilized (40 CFR 141.852). The sample is logged in before it arrives, and the label prints once.
3. 3
   
   ### Receipt and the hold-time clock
   
   Drinking water (40 CFR 141): a total coliform sample must start incubation within 30 hours of collection. Nitrate has 48 hours, or 14 days if the sample is chlorinated, not acidified and kept at 4 °C (40 CFR 141.23(k)(2)). The LIMS should show the time left and warn before it runs out. [Compare hold times by program](https://prismalims.com/sample-holding-times#ht-coliform-dw).
4. 4
   
   ### Batch with QC
   
   Samples run in batches with the blanks, spikes and duplicates your method calls for. A failed QC check should stop the batch before a result goes out.
5. 5
   
   ### Review
   
   A second person checks each result against its QC and limits. Every change is kept, with who made it and when.
6. 6
   
   ### The state file and the report
   
   The client gets its report. The state gets the same results in its own format, such as a CMDP upload. Both come from one record, so the numbers match.

![Prisma LIMS incubator screen: total coliform and E. coli tests with incubation timers and status, from incubating to max incubation done](https://prismalims.com/hs-fs/hubfs/website%20assets/images/features-operational-control-800.webp?width=2000&height=1397&name=features-operational-control-800.webp)

The Prisma LIMS incubator view: coliform tests with their incubation timers and status.

Wastewater samples under the Clean Water Act follow a different hold-time table. See our [wastewater LIMS guide](https://prismalims.com/wastewater-lims) for that side of the work.

Long analyte lists

## PFAS in drinking water: Methods 533 and 537.1

EPA has two methods for PFAS in drinking water. Method 533 (2019) measures 25 PFAS with isotope dilution. Method 537.1 (2018, updated to version 2.0 in 2020) measures 18 PFAS, including HFPO-DA. Both use solid phase extraction and LC/MS/MS. A drinking water LIMS must hold each method’s full analyte list and report every analyte with its QC. Read more in our guide to [PFAS testing LIMS for Methods 533 and 537.1](https://prismalims.com/pfas-testing-lims).

Before you buy

## What to ask any drinking water LIMS vendor

Bring these five questions to every demo. Ask for the answer on your own methods and files.

Ask any vendor

- Can you show our state’s file, or a CMDP upload, built from our own results?
- Will you set up our methods, analytes and limits, or will our staff do it?
- How does the system show time left on a coliform sample, and warn before it runs out?
- Does it handle bottle kits and pre-login from the water system’s schedule, and print the labels?
- Can we test it with our own data in a test system before go-live?

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

Where we fit

## Where Prisma LIMS fits, and where it does not

Prisma LIMS is a cloud LIMS for environmental testing labs in the US and Canada. We set it up for your lab, move your data, train your team, and run the hosting and support.

- Prisma LIMS supports drinking water lab workflows: hold-time tracking and batches with QC.
- Prisma LIMS builds the CMDP file; a lab user uploads it to the state.
- Done-for-you means we do the work: we map your workflow, set up your methods and reports, move your data, test it with you in a sandbox, train your team on-site, and stay with you through go-live.
- Methods running on Prisma LIMS today: EPA 524, 525 and 552, and THMs; EPA 200.7 and 200.8, and SW-846 6010 and 6020; total coliform and E. coli; BOD and TSS.
- Every client gets a shared Slack channel with us. We usually reply within 2 hours and fix most bugs within 48 hours.
- Accreditation belongs to the lab. Prisma LIMS keeps chain of custody and a full audit trail of who changed what and when.

### Built for

Prisma LIMS is built only for environmental labs: mid-sized and large commercial, municipal and utility labs that test water, wastewater, drinking water, soil and sludge, in the US and Canada. Other environmental matrices are on request.

[Who Prisma LIMS is for](https://prismalims.com/who-its-for)

### Not a fit for

Prisma LIMS is not a fit for clinical-only or pharma-only labs, very small labs, or labs that prefer to build and run their own system.

### What it costs

Setup is a one-time fee. After go-live there is one monthly fee that covers hosting, updates, support and every user. We give you a range on our first call and a written quote for your lab.

[How LIMS pricing works](https://prismalims.com/lims-total-cost-of-ownership#pricing-models)

### How you get live

You get a test system loaded with your own data in about 90 days. You run it next to your current process for an agreed side-by-side period, then we go live on your sign-off. Dates depend on how fast your team gives us methods and data.

[The path to go-live, step by step](https://prismalims.com/how-it-works)

Back to why

## The right result reaches the state on time

When the clock, the QC and the state file live in one record, results go out on time and they match. The water system stays on its schedule, and your lab keeps its client’s trust.

Ask us to show it on your own methods and files.

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

## Questions drinking water labs ask

What is SDWIS?

SDWIS is the Safe Drinking Water Information System, EPA’s federal database of the drinking water data states report, from each system’s details to its violations. More in [SDWIS and CMDP in plain words](https://prismalims.com/drinking-water-lims#sdwis-cmdp).

What is CMDP?

CMDP is EPA’s Compliance Monitoring Data Portal, the tool utilities and labs use to send drinking water data to the state electronically. More in [SDWIS and CMDP in plain words](https://prismalims.com/drinking-water-lims#sdwis-cmdp).

What does UCMR mean?

UCMR means Unregulated Contaminant Monitoring Rule. Under it, public water systems sample for contaminants that do not have health-based standards yet. EPA uses the data to decide whether to regulate them. UCMR 6 was proposed on July 1, 2026, and is still a proposed rule.

Is NELAP accreditation the same as drinking water certification?

No. State drinking water lab certification lets a lab analyze compliance samples under the Safe Drinking Water Act. It asks for approved methods, PT samples and on-site audits. NELAP accreditation is a separate program, where state agencies accredit environmental labs to the TNI Standard. Which ones your lab needs depends on your state and your work.

What is the TNI standard?

The TNI standard is the consensus standard that NELAP accreditation bodies use to accredit environmental labs. TNI, a non-profit, writes its standards through a consensus process. Most NELAP accreditation bodies list the 2016 TNI Environmental Laboratory Sector Standard. For the records state rules ask for, see [NELAP and TNI records: what to check in a LIMS](https://prismalims.com/nelap-tni-lims-requirements).

What does it mean to be an accredited lab?

An accredited lab has been checked by an outside body against a written standard, for the tests on its scope. For environmental labs, one route is NELAP accreditation to the TNI standard. A drinking water lab also needs EPA or state certification for the compliance analyses it runs. A few measurements, such as pH, turbidity and disinfectant residual, are exceptions (40 CFR 141.28). The certificate is always the lab’s, never the software’s.

How long can a drinking water coliform sample be held?

A drinking water total coliform sample must start incubation within 30 hours of collection (40 CFR 141.852). That is a Safe Drinking Water Act rule. Wastewater samples follow a different Clean Water Act table: see [sample holding times for each program](https://prismalims.com/sample-holding-times).

What LIMS is good for a drinking water lab that reports to the state?

One that keeps the water system’s schedule, the coliform clock, batch QC and the state file in one record, shown on your own methods. Prisma LIMS builds the CMDP file, and a lab user uploads it to the state. For the rest of our part, see [Where Prisma LIMS fits](https://prismalims.com/drinking-water-lims#fit).

## Keep reading

- ### Environmental LIMS guide
  
  Picking a LIMS is a long bet. See what any environmental LIMS must handle. Then use the checklist to compare.
  
  [How to compare environmental LIMS](https://prismalims.com/environmental-lims)
- ### Sample holding times
  
  A missed clock is a lost result. See common EPA hold times, by program. Learn how a LIMS keeps each clock.
  
  [Hold times and batch QC](https://prismalims.com/sample-holding-times)
- ### Wastewater LIMS
  
  Permit reports leave no slack. See what a wastewater lab needs. Then check any system against it.
  
  [What a wastewater lab needs from a LIMS](https://prismalims.com/wastewater-lims)
- ### Chain of custody
  
  A gap in the record can sink a result. See what a COC must record. Learn how a LIMS keeps each hand-off.
  
  [Chain of custody, hand-off by hand-off](https://prismalims.com/chain-of-custody-software)
- ### CMDP in a water lab
  
  State uploads take time. Read how labs work with CMDP. See where the time goes.
  
  [CMDP reporting in a water lab](https://prismalims.com/blog/incorporating-the-compliance-monitoring-portal-cmdp-effectively)
- ### Rules for certified labs
  
  The rules shape the daily work. Read an overview for certified drinking water labs. Use it to plan ahead.
  
  [Drinking water lab certification: the rules](https://prismalims.com/blog/navigating-the-regulatory-landscape-for-certified-drinking-water-labs)
- ### EDD formats
  
  Clients and states load your results into their own systems. See what an EDD holds, and why files get rejected.
  
  [EDD formats for environmental labs](https://prismalims.com/blog/edd-formats-environmental-labs)

Last checked: 24 November 2026. Next check due: 24 February 2027 (UCMR 6 is a proposed rule).

Rules change. Always check the current rule with EPA and your state before you rely on it.

## Schedule an online demo

The first call is a 30-minute Lab Systems Diagnostic. Then we show Prisma LIMS on your own files.

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

[contact@prismalims.com](mailto:contact@prismalims.com) [(224) 347-6794](tel:+12243476794)

[![](https://prismalims.com/hs-fs/hubfs/website%20assets/logos/prisma-lims-logo-1-line-white-340.webp?width=170&height=30&name=prisma-lims-logo-1-line-white-340.webp)](https://prismalims.com/)

A cloud LIMS built only for environmental labs in the US and Canada. Based in Illinois, US.

Book a call

[Schedule an online demo](https://meetings.hubspot.com/dacian-florea)

Email or call

[contact@prismalims.com](mailto:contact@prismalims.com)

[(224) 347-6794](tel:+12243476794)

The first call is a 30-minute Lab Systems Diagnostic.

Company

- [Home](https://prismalims.com/)
- [How You Get Live](https://prismalims.com/how-it-works)
- [Pricing](https://prismalims.com/pricing)
- [Who It’s For](https://prismalims.com/who-its-for)
- [About Us](https://prismalims.com/about)
- [Blog](https://prismalims.com/blog)

Labs we serve

- [Environmental LIMS](https://prismalims.com/environmental-lims)
- [Commercial environmental labs](https://prismalims.com/commercial-lab-lims)
- [Municipal and treatment-plant labs](https://prismalims.com/municipal-lab-lims)

Sample types

- [Water LIMS](https://prismalims.com/who-its-for#water)
- [Wastewater LIMS](https://prismalims.com/wastewater-lims)
- [Drinking water LIMS](https://prismalims.com/drinking-water-lims)
- [Soil, sludge and biosolids](https://prismalims.com/soil-lims)

Guides

- [Cloud LIMS](https://prismalims.com/cloud-lims)
- [Chain of custody software](https://prismalims.com/chain-of-custody-software)
- [Sample holding times](https://prismalims.com/sample-holding-times)
- [TCLP and SPLP](https://prismalims.com/tclp-splp-leaching)
- [PFAS testing](https://prismalims.com/pfas-testing-lims)
- [NELAP and TNI records](https://prismalims.com/nelap-tni-lims-requirements)
- [LIMS cost over five years](https://prismalims.com/lims-total-cost-of-ownership)
- [Compare environmental LIMS vendors](https://prismalims.com/compare)

© 2026 Prisma LIMS. [Cookie Policy](https://prismalims.com/cookie-policy)

- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/linkedin-48.webp?width=24&height=24&name=linkedin-48.webp)](https://www.linkedin.com/company/prismalims/)
- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/youtube-48.webp?width=24&height=24&name=youtube-48.webp)](https://www.youtube.com/@PrismaLIMS)
- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/facebook-48.webp?width=24&height=24&name=facebook-48.webp)](https://www.facebook.com/prismalims/)
- [![](https://prismalims.com/hs-fs/hubfs/website%20assets/icons/instagram-48.webp?width=24&height=24&name=instagram-48.webp)](https://www.instagram.com/prismalims/)

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/#organization",
  "@type" : "Organization",
  "address" : {
    "@type" : "PostalAddress",
    "addressCountry" : "US",
    "addressRegion" : "IL"
  },
  "alternateName" : [ "PrismaLIMS", "LIMs-Plus" ],
  "areaServed" : [ {
    "@type" : "Country",
    "name" : "United States"
  }, {
    "@type" : "Country",
    "name" : "Canada"
  } ],
  "contactPoint" : {
    "@type" : "ContactPoint",
    "availableLanguage" : "English",
    "contactType" : "sales",
    "email" : "contact@prismalims.com",
    "telephone" : "+1-224-347-6794"
  },
  "description" : "Prisma LIMS is a cloud LIMS for environmental testing labs in the US and Canada. We set it up for your lab, move your data, train your team, and run the hosting and support.",
  "email" : "contact@prismalims.com",
  "founder" : {
    "@id" : "https://prismalims.com/about#dacian-florea",
    "@type" : "Person",
    "name" : "Dacian Florea",
    "sameAs" : [ "https://www.linkedin.com/in/dacian-florea/" ]
  },
  "foundingDate" : "2021",
  "knowsAbout" : [ "Laboratory information management systems", "Environmental laboratory software", "Cloud LIMS", "Wastewater testing", "Drinking water testing", "Soil and sludge testing", "Chain of custody", "Sample holding times", "TCLP and SPLP leaching", "PFAS testing methods", "TNI and NELAP accreditation records" ],
  "logo" : {
    "@id" : "https://prismalims.com/#logo",
    "@type" : "ImageObject",
    "caption" : "Prisma LIMS",
    "height" : 512,
    "url" : "https://48211686.fs1.hubspotusercontent-na1.net/hubfs/48211686/website%20assets/logos/prisma-lims-favicon-512.png",
    "width" : 512
  },
  "name" : "Prisma LIMS",
  "sameAs" : [ "https://www.linkedin.com/company/prismalims/", "https://www.youtube.com/@PrismaLIMS", "https://www.facebook.com/prismalims/", "https://www.instagram.com/prismalims/" ],
  "telephone" : "+1-224-347-6794",
  "url" : "https://prismalims.com/"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/#website",
  "@type" : "WebSite",
  "alternateName" : [ "PrismaLIMS", "LIMs-Plus" ],
  "inLanguage" : "en-US",
  "name" : "Prisma LIMS",
  "publisher" : {
    "@id" : "https://prismalims.com/#organization"
  },
  "url" : "https://prismalims.com/"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/drinking-water-lims#webpage",
  "@type" : "WebPage",
  "about" : {
    "@id" : "https://prismalims.com/#organization"
  },
  "breadcrumb" : {
    "@id" : "https://prismalims.com/drinking-water-lims#breadcrumb"
  },
  "dateModified" : "2026-11-26",
  "description" : "What a certified drinking water lab needs from its LIMS: short hold times, batch QC, state files such as CMDP, UCMR, PFAS methods and SDWIS explained.",
  "inLanguage" : "en-US",
  "isPartOf" : {
    "@id" : "https://prismalims.com/#website"
  },
  "mainEntity" : {
    "@id" : "https://prismalims.com/drinking-water-lims#article"
  },
  "name" : "Drinking Water LIMS for Certified Labs - Prisma LIMS",
  "url" : "https://prismalims.com/drinking-water-lims"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/drinking-water-lims#article",
  "@type" : "Article",
  "author" : {
    "@id" : "https://prismalims.com/#organization",
    "@type" : "Organization",
    "name" : "Prisma LIMS"
  },
  "dateModified" : "2026-11-26",
  "datePublished" : "2026-11-24",
  "headline" : "Drinking water LIMS: what a certified drinking water lab needs",
  "image" : "https://48211686.fs1.hubspotusercontent-na1.net/hubfs/48211686/website%20assets/images/featured%20images/og-drinking-water-lims.jpg",
  "inLanguage" : "en-US",
  "mainEntityOfPage" : {
    "@id" : "https://prismalims.com/drinking-water-lims#webpage"
  },
  "publisher" : {
    "@id" : "https://prismalims.com/#organization"
  }
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://prismalims.com/drinking-water-lims#breadcrumb",
  "@type" : "BreadcrumbList",
  "itemListElement" : [ {
    "@type" : "ListItem",
    "item" : "https://prismalims.com/",
    "name" : "Home",
    "position" : 1
  }, {
    "@type" : "ListItem",
    "item" : "https://prismalims.com/environmental-lims",
    "name" : "Environmental LIMS",
    "position" : 2
  }, {
    "@type" : "ListItem",
    "item" : "https://prismalims.com/drinking-water-lims",
    "name" : "Drinking water LIMS",
    "position" : 3
  } ]
}
```